| Directive Compliance | EMC Directive, RoHS Directive | 
		
			| Supply Voltage | 12 to 24 V DC +10-15% Ripple P-P 10 % or less | 
		
			| Power Consumption | Normal operation: 960 mW or less (current consumption 40 mA or less at 24 V supply voltage) ECO mode: 720 mW or less (current consumption 30 mA or less at 24 V supply voltage)
 | 
		
			| Communication Output (C/Q): IO-Link Communication | IO-Link Specification V1.1 (Note:)When the sensor is used as an ordinary sensor, the communication output (C/Q) provides the same output operation as the control output (DO).
 | 
		
			| Communication Output (C/Q): Baud Rate | COM3 (230.4 kbps) (Note:)When the sensor is used as an ordinary sensor, the communication output (C/Q) provides the same output operation as the control output (DO).
 | 
		
			| Communication Output (C/Q): Process Data | 4 byte (Note:)When the sensor is used as an ordinary sensor, the communication output (C/Q) provides the same output operation as the control output (DO).
 | 
		
			| Communication Output (C/Q): Minimum Cycle Time | 1.0 ms (Note:)When the sensor is used as an ordinary sensor, the communication output (C/Q) provides the same output operation as the control output (DO).
 | 
		
			| Control Output (DO) | PNP open-collector transistor • Maximum source current: 50 mA
 • Applied voltage: 30 V DC or less (between output and +V)
 • Residual voltage: 2 V or less (Note) (at maximum source current)
 (Note:)In case of using the cable (cable length 2 m 6.562 ft).
 | 
		
			| Control Output (DO): Output Operation | Switchable either Light-ON or Dark-ON by L/D mode | 
		
			| Control Output (DO): Short-Circuit Protection | Incorporated | 
		
			| Response Time | STD: 250 μs or less, LONG: 2 ms or less, U-LG: 4 ms or less, HYPR: 24 ms or less, selectable | 
		
			| Sensitivity Setting | 2-point teaching / Limit teaching / Full-auto teaching / Manual adjustment | 
		
			| Incident Light Sensitivity Setting | Incorporated, 4 steps | 
		
			| Incident Light Intensity Display Range | STD: 0 to 4,000, LONG: 0 to 8,000, U-LG / HYPR: 0 to 9,999 | 
		
			| Timer Function | Incorporated with variable OFF-delay / ON-delay / One-shot, switchable either effective or ineffective | 
		
			| Timer Function: Timer Period | 0.1 to 999.9 ms approx., in units of 0.1 ms approx. | 
		
			| Different Frequency Interference Prevention Function | Incorporated (up to 4 units). Note that the response time varies depending on the setting. F-1: 0.8 ms or less, F-2: 0.9 ms or less, F-3: 1.0 ms or less, F-4: 1.7 ms or less
 (Note:)This function increases the hysteresis. Check the sensing condition when using the function.
 | 
		
			| Protection | IP40 (IEC) | 
		
			| Ambient Temperature | -10 to +55℃ +14 to +131℉ (If 4 to 7 units are mounted in cascade: -10 to +50℃ +14 to +122℉ or if 8 to 16 units are mounted in cascade: -10 to +45℃ +14 to +113℉) (No dew condensation or icing allowed), Storage: -20 to +70℃ -4 to +158℉ | 
		
			| Emitting Element (Modulated) | Red LED (Peak emission wavelength: 660 nm 0.026 mil) | 
		
			| Material | Enclosure, Case cover: Polycarbonate, Switch: Polyacetal | 
		
			| Cable | 0.2 mm2 cabtyre cable with M12 connector, 0.3 m 0.984 ft long | 
		
			| Cable Extension | Extension up to total 20 m 65.617 ft is possible with 0.3 mm2, or more, cable. (Condition of CE compliance: less tan 20 m 65.617 ft) (however, supply voltage 12 V DC or more)
 | 
		
			| Weight (Typ.) | Net weight: 35 g approx., Gross weight: 60 g approx. | 
		
			| Remark | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23℃ +73.4℉. | 
		
			| Vibration Resistance | 10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude (10 G max.) in X, Y and Z directions for two hours each | 
		
			| Shock Resistance | 98 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each |